Tripela Fes Eneji Mita

Tripela Fes Eneji Mita Saplaia long Saina

 

Mipela i wanpela profesenel saplaia bilong tripela-feis eneji mita, na mipela i save givim ol hai-presisen mita solusen bilong ol indastrial sistem, ol komesel bilding, na ol yutiliti-skel eneji monitoring projek, wantaim bihainim IEC 62052, IEC 62053, ISO na MID standet.

 

 
 
3 Phase Din Rail Meter Of 4P

Bilong wanem ol Global Baia i Trastim Tripela Fes Eneji Mita Bilong Mipela

 

Mipela i sapotim ol kastoma bilong wol wantaim:

• Faktori-dairekt manufakturing wantaim stebol prodaksen kapasiti
• Indastrial-greid stretpela bilong ol aplikesen bilong biling
• IEC / MID / CE kompliant prodak ranj
• Smat metering integresen (AMR / AMI redi)
• Strongpela OEM na ODM enjiniaring inap

 

Paramita

 

I stret

Klas 1 bilong ektiv eneji, Klas 2 bilong reaktiv eneji (opsenel)

Reit Voltej

3×230V

Reit Karent

5 - 100A

Pulse konstan

1000 imp/kWh

Frikwensi

50Hz

Gret bilong insulesen

Klas II

 

 
Ol wok bilong tripela hap pawa mita
 

Ol i save yusim planti tripela feis mita bilong mipela long ol global eneji infrastraksa projek.

01/

Yutiliti na Grid Sabstesen Otomesen
Hai-presisen Klas 0.5S/0.2S mita wantaim tupela sait eneji traking, sapotim DLMS/COSEM na IEC 61850 bilong seamless HES/MDM integresen.

02/

Indastrial Eneji Menesmen na SCADA
DIN-rail na panel mita wantaim RS485 Modbus na Ethernet bilong gutpela indastrial monitoring na SCADA sistem.

03/

Komesel Riel Estet & Planti Tenant Biling
Multi-tariff billing, data logging, na anti-tamper proteksen bilong stretpela na seif eneji menesmen insait long ol komesel bilding.

04/

Riniubel Eneji na Maikrogrid
Net metering bilong sola, win, na EV sistem wantaim 'real-time import/export tracking na data sapot bilong eneji ripoting.

 

Save bilong wokim ol samting na save long wok enjiniaring

 

Inkoming Kwaliti Kontrol (IQC)

100% sekim bilong ol bikpela samting we i gat ol 'microcontrollers', ol 'high-stability current transformers' (CT), na ol 'flame-retardant enclosures' bilong V0-greid bilong stopim ol hevi bilong paia.

01

100% Hai-Presisen Kalibresen

Yusim ol 'multi-positions automatic calibration benches' long sekim 'accuracy class' aninit long planti 'power factors' (PF=0.5L, 1.0, 0.8C) na ol kain kain 'temperature loop'.

02

Envairomen Stres na Paia-Insait

Olgeta mita i save kisim 'accelerated aging' na 'heat soak testing' (55 digri i go inap 70 digri) aninit long 'full load simulation' bilong rausim namba bilong ol bebi we i save dai hariap.

03

Strongpela EMC na Surge Immunity

Ol i bin sekim long haus leb bilong mipela long sanap strong long ol bikpela laitning (inap long 4kV/6kV standet, inap long skruim i go long 12kV), ol 'electrostatic discharges' (ESD), na ol 'electromagnetic fields'.

04

Batch Traceability

Olgeta mita i gat wanpela 'serial namba' insait long en, na i save bungim wantaim ol spesifik komponen bilong en, deit bilong prodaksen lain, na ol 'calibration data logs' bilong bihainim laiptaim bilong en.

05

 

 

Intanesenel Standet na Setifikesen

Ol tripela-feis pawa mita bilong mipela i kamap long inapim ol lo bilong wol:

• IEC 62052-11 (Ol samting yu mas mekim)
• IEC 62053 series (Accuracy standards)
• MID setifikesen (Bihainim ol Yuropian biling rikwaemen)
• CE setifikesen (Bihainim ol sefti rikwaemen bilong EU)
• ISO 9001 Kwaliti Menesmen Sistem

3 Phase Prepaid Electricity Meters

 

 

Ol askim we planti taim

 

 

Q: Ol smat mita bilong yu i sapotim wok wantaim ol Head-End Systems (HES) bilong ol narapela lain?

A: Yes. Ol tripela-smat mita bilong mipela i bihainim gut ol standet bilong DLMS/COSEM (IEC 62056). Ol i bin sekim olsem ol i ken wok gut wantaim ol bikpela global AMI/AMR pletfom, na mekim olsem 'plug-' na '-plei i ken wok bung wantaim na i no gat 'proprietary vendor lock-in.

Q: Olsem wanem ol mita bilong yu i save lukautim ol pawa kwaliti iven na anti-tampering?

A: Ol mita bilong mipela i gat wanpela non-volatile memori bilong rekodim ol bikpela pawa kwaliti iven (olsem voltej i pundaun, swel, fes i lus, na karent i no balens). Long anti-tampering, ol i save painim na logim ol op bilong 'terminal cover' (maski ol i no gat pawa), ol i traim long abrusim, ol 'reverse wiring', na ol strongpela 'magnetic field interferences', na kwiktaim ol i save kirapim ol toksave long rot bilong 'communication module'.

Q: Wanem taim bilong yu long kisim ol kastom OEM/ODM oda?

A: Long ol standet konfigurasen o ol evaluesen sempel, taim bilong mipela em 7-10 de. Long ol bikpela OEM oda we i gat ol plastik mol we ol i wokim long laik bilong ol yet, ol narakain 'terminal block' konfigurasen, o ol 'firmware'/protokol we ol i wokim long laik bilong ol yet, bikpela prodaksen i save kisim 4 i go inap 6 wik, na dispela i dipen long sediul bilong painim ol komponen.

Q: Ol mita bilong yu inap long karim tupela -sos o bekap jenereta biling?

A: Yes. Mipela i save givim ol 'firmware' konfiguresen we i sapotim 'multi-channel profiling'. Ol mita i ken separetim yutiliti grid konsumsen long auxiliary/bekap jenereta treking long rot bilong ol ekstenel dijitel input, na dispela i mekim klia tarif alokesen bilong ol maikrogrid.

Olsem wanpela bilong ol profesenel tripela feis eneji mita manifakta na saplaia long Saina stat long 1994, mipela i gat ol wol-lida prodaksen ikwipmen na strongpela manufakturing kapabiliti. Plis yu no ken wari long baim bikpela namba bilong tripela feis eneji mita long faktori bilong mipela.